Cylindrical External Hex Ø4.0

TCE4007 for height of 7 mm.
TCE4085 for height of 8.5 mm.
TCE4010 for height of 10 mm.
TCE4011 for height of 11.5 mm.
TCE4013 for height of 13 mm.
TCE4015 for height of 15 mm.


Platform Ø4.1 mm, implant Ø4 mm, hexagon 2.7 mm. 
The micro-threading in the coronal part has the objective of reducing bone reabsorption, therefore improving long-term performance.
The apical incisions allow the implant to become self-taping and enable it to be inserted with ease, also guaranteeing excellent anti-rotational properties.

Straight abutment

Cod. TCFEMD412 - H2
Cod. TCFEMD414 - H4
Cod. TCFEMD416 - H6

Angled abutment 15°

Cod. TCFEMA15°412 - H2
Cod. TCFEMA15°414 - H4
Cod. TCFEMA15°416 - H6

Angled abutment 25°

Cod. TCFEMA25°412 - H2
Cod. TCFEMA25°414 - H4
Cod. TCFEMA25°416 - H6

Castable abutment

Cod. TCFECA41N

Rotating castable abutment

Cod. TCFECA41R

Non-rotating provisional abutment

Cod. TCFEMP41N

Rotating provisional abutment

Cod. TCFEMP41R

Ucla titanium base abutment with cannula

Cod. TCFEUC41N

Ball abutment

Cod. TCFEMS411 - H1
Cod. TCFEMS412 - H2
Cod. TCFEMS413 - H3
Cod. TCFEMS414 - H4

Ball abutment cap

Cod. MSCAP01

Stainless box for ball abutment cap

Cod. MSCON01

Castable abutment for MFA

Cod. TIS900002

Provisional abutment for MFA

Cod. TIS100222

Prosthetic screw M1,4 for MFA

Cod. TIS100003

Positioner for angled MFA

Cod. TPOMFA

Transfer pick-up techinque

Cod. TCFETR41

Transfer pull-up technique

Cod. TCFETRST41

Transfer screw

Cod. TCFEVTRST

Analogue for implant Ø4,1

Cod. TCFEAN41

Healing screw

Cod. TCFEVG412  - H2
Cod. TCFEVG414  - H4
Cod. TCFEVG416  - H6

Transfer for MFA

Cod. TIS900003

Transfer screw for MFA

Cod. TIS900004

Analogue for MFA

Cod. TIS900001

Healing screw H4 with ring

Cod. TIS100304

Pick-up transfer screw

Cod. TCFEVPL

Prosthetic screw with torx connection

Cod. TCFEVPR

Placement key for angled MFA

Cod. TPOMFA

Screw for angled MFA

Cod. TIS100001

Castable cannula for MFA

Cod. TIS900002

Angled MFA 17°

Cod. TCFE17°4120 - H2
Cod. TCFE17°4130 - H3
Cod. TCFE17°4140 - H4

Angled MFA 30°

Cod. TCFE30°4130 - H3
Cod. TCFE30°4140 - H4
Cod. TCFE30°4150 - H5

Straight MFA

Cod. TCFE00°4110 - H1
Cod. TCFE00°4120 - H2
Cod. TCFE00°4130 - H3
Cod. TCFE00°4140 - H4

Drill extension

Cod. TPRFR

Lanceolate drill

Cod. TFRLANC

Cylindrical drill

Cod. TFRC20

Cylindrical drill Ø2,8

Cod. TFRC28

Cylindrical drill Ø3,4

Cod. TFRC34

Threadformer for cylindrical implant Ø4

Cod. TCEIMS40

Short hand driver

Cod. TDR12C

Long hand driver

Cod. TDR12L

Driver for hand and ratchet

Cod. TCR12L

Micromotor driver for mounter and treahdformer

TCONTR

Parallelism indicator

Cod. TIND

Depth gauge

Cod. TMPRF

Mounter blocking key

Cod. TCHBM

Dynamometric ratchet

Cod. TDINA

Driver for straight MFA

Cod. TCRMFA

Ball abutment driver

Cod. 771CEF

STOP TFRC20

Cod. TSTOPC20XX
(07/85/10/11/13/15)

STOP TFRC28

Cod. TSTOPC28XX
(07/85/10/11/13/15)

STOP TFRC34

Cod. TSTOPC34XX
(07/85/10/11/13/15)
 

Surgical sequence Ø 4.0

For the correct insertion of the cylindrical external hexagon Ø 4.0 implant, we recommend following the surgical protocol:

1. Use the lanceolate drill (TFRLANC) up to the marking (recommended n. revs = 800 rpm).
2. Use the 2 mm start-up drill (TFRC20) with the appropriate stop of the same height as the implant being inserted (recommended n. revs = 800 rpm).
3. Insert the parallelism indicator and check for any disparallelism.
4. Use the cylindrical drill Ø 2.8 (TFRC28) with the appropriate stop (recommended n. revs = 200-400 rpm).
5. Use the final cylindrical drill Ø 3.4 (TFRC34) with the appropriate stop (recommended n. revs = 200-400 rpm).
6. In the case of D1 bone density, use the threadformer (TCEIMS40)
7. Insert the implant.Recommended n. of revs 15-25 rpm.
8. Close with the screw cap included in the package.