Cod. TCFEMD502 - H2
Cod. TCFEMD504 - H4
Cod. TCFEMD506 - H6
Cod. TCFEMA15°502 - H2
Cod. TCFEMA15°504 - H4
Cod. TCFEMA15°506 - H6
Cod. TCFEMA25°502 - H2
Cod. TCFEMA25°504 - H4
Cod. TCFEMA25°506 - H6
Cod. TCFECA50N
Cod. TCFECA50R
Cod. TCFEMP50N
Cod. TCFEMP50R
Cod. TCFEUC50N
Cod. TCFEMS501 - H1
Cod. TCFEMS502 - H2
Cod. TCFEMS503 - H3
Cod. TCFEMS504 - H4
Cod. MSCAP01
Cod. MSCON01
Cod. TCFETRST50
Cod. TCFEVTRST
Cod. TCFEAN50
Cod. TCFEVG502 - H2
Cod. TCFEVG504 - H4
Cod. TCFEVG506 - H6
Cod. TCFEVPL
Cod. TCFEVPR
Cod. TPRFR
Cod. TFRLANC
Cod. TFRC20
Cod. TFRF32
Cod. TFRF40
Cod. TFRF50
Cod. TFEIMS40
Cod. TDR12C
Cod. TDR12L
Cod. TCR12L
TCONTR
Cod. TIND
Cod. TMPRF
Cod. TCHBM
Cod. TDINA
Cod. 771CEF
Cod. TSTOPC20XX
(07/85/10/11/13/15)
Cod. TSTOPC35XX
(07/85/10/11/13/15)
Cod. STOP45XX
(07/85/10/11/13/15)
Cod. STOP50XX
(07/85/10/11/13/15)
For the correct insertion of the conical external hexagon Ø 5.0 implant, we recommend following the surgical protocol:
1. Use the lanceolate drill (TFRLANC) up to the marking (recommended n. revs = 800 rpm).
2. Use the 2 mm start-up drill (TFRC20) with the appropriate stop of the same height as the implant being inserted (recommended n. revs = 800 rpm).
3. Insert the parallelism indicator and check for any disparallelism.
4. Use the conical drill Ø 3.25 (TFRF32) with the appropriate stop (recommended n. revs = 200-400 rpm).
5. Use the final drill Ø 4.0 (TFRF40) with the appropriate stop (recommended n. revs = 200-400 rpm).
6. Use the final conical drill Ø 5.0 (TFRF50) with the appropriate stop (recommended n. revs = 200-400 rpm).
7. In the case of D1 bone density, use the threadformer (TFEIMS50).
8. Insert the implant. Recommended n. of revs 15-25 rpm.
9.Close with the screw cap included in the package.