TiSmart2 Ø5,0

Product codes:
Cod. TCE5007C for height of 7 mm.
Cod. TCE5085C for height of 8,5 mm.
Cod. TCE5010C for height of 10 mm.
Cod. TCE5011C for height of 11,5 mm.
Cod. TCE5013C for height of 13 mm.
Cod. TCE5015C for height of 15 mm.

Straight abutment

Cod. TSKMD15 - H1,5
Cod. TSKMD30 - H3,0

Angled abutment 15°

Cod. TSKMA152 - H2
Cod. TSKMA153 - H3

Angled abutment 25°

Cod. TSKMA252 - H2
Cod. TSKMA253 - H3

Abutment with cobalt chrome base

Cod. TSKCRCO

Castable abutment cobalt chrome rotating base

Cod. TSKCRCOR

Castable abutment titanium base

Cod. TSKCATI

Provisional abutment

Cod. TSKMPN

Rotating provisional abutment

Cod. TSKMPR

Milleable titanium abutment

Cod. TSKMF

T-base

Cod. TSKTI

Rotating T-base

Cod. TSKTIR

Titanium scan body abutment

Cod. TSKSCB

Ball abutment

Cod. TSKMS1 - H1
Cod. TSKMS2 - H2
Cod. TSKMS4 - H4

Ball abutment cap

Cod. MSCAP01

Stainless box for ball abutment cap

Cod. MSCON01

CAD CAM abutment

Cod. TSKCAM

Prosthetic screw

Cod. TSKVPR

Prosthetic screw with torx connection

Cod. TSKVPT

Straight MFA TSK

Cod. TSK001 - H1
Cod. TSK002 - H2
Cod. TSK003 - H3

Angled MFA 17° TSK

Cod. TSK173 - H3
Cod. TSK174 - H4

Angled MFA 30° TSK

Cod. TSK303 - H3
Cod. TSK304 - H4

Prosthetic screw for MFA

Cod. TSK100001

Castable abutment for MFA

Cod. TIS900002

Provisional abutment for MFA

Cod. TIS100222

Prosthetic screw M1,4 for MFA

Cod. TIS100003

Positioner for angled MFA

Cod. TPOMFA

Transfer pick-up techinque

Cod. TSKTR

Short transfer for Pick-up technique

Cod. TSKTRSH

Screw for short transfer

Cod. TSKVTR

Transfer pull-up technique

Cod. TSKTRST

Pull-up transfer screw

Cod. TSKVTRST

Analogue for conic connection implant Ø3,5

Cod. TSKAN35

Healing screw

Cod. TSKVG2 - H2
Cod. TSKVG4 - H4
Cod. TSKVG6 - H6

Healing screw Ø4,5

Cod. TSKVG452 - H2
Cod. TSKVG454 - H4
Cod. TSKVG456 - H6

Healing screw Ø5,5

Cod. TSKVG552 - H2
Cod. TSKVG554 - H4
Cod. TSKVG556 - H6

Transfer for MFA

Cod. TIS900003

Transfer screw for MFA

Cod. TIS900004

Analogue for MFA

Cod. TIS900001

Healing screw H4 with ring

Cod. TIS100304

Drill extension

Cod. TPRFR

Lanceolate drill

Cod. TFRLANC

Cylindrical drill

Cod. TFRC20

Conical drill Ø3.5

Cod. TFRK35

Conical drill Ø4.0

Cod. TFRK40

Conical drill Ø4.8

Cod. TFRK48

Cortical drill Ø3.5

Cod. TFRKC35

Cortical drill Ø4.0

Cod. TFRKC40

Cortical drill Ø4.8

Cod. TFRKC48

Micromotor driver

Cod. TSKDR

Micromotor driver

Cod. TFIINS

Short hand driver

Cod. TDR12C

Long hand driver

Cod. TDR12L

Short driver with torx connection

Cod. TDR12CT

Long driver with torx connection

Cod. TDR12LT

Driver for hand and ratchet

Cod. TCR12L

Parallelism indicator

Cod. TIND

Depth gauge

Cod. TMPRF

Dynamometric ratchet

Cod. TDINA

Driver for straight MFA

Cod. TCRMFA

Ball abutment driver

Cod. 771CEF

STOP TFRC20

Cod. TSTOPC20XX
(07/85/10/11/13/15)

STOP TFRK35

Cod. TSTOPC35XX
(07/85/10/11/13/15)

STOP TFRK40

Cod. TSTOPC34XX
(07/85/10/11/13/15)

STOP TFRK48

Cod. TSTOPC42XX
(07/85/10/11/13/15)

Surgical sequence Ø 5.0

For the correct insertion of the Ti Smart Ø 5.0 implant, we recommend following the surgical protocol:

1. Use the lanceolate drill (TFRLANC) up to the marking (recommended n. revs = 800 rpm).
2. Use the 2 mm start-up drill (TFRC20) with the appropriate stop of the same height as the implant being inserted (recommended n. revs = 800 rpm).
3. Insert the parallelism indicator and check for any disparallelism.
4. Use the conical drill (TFRK35) with the appropriate stop (recommended n. revs = 200-400 rpm).
5. Use the conical drill (TFRK40) with the appropriate stop (recommended n. revs = 200-400 rpm).
6. Use the final conical drill (TFRK48) with the appropriate stop (recommended n. revs = 200-400 rpm).
7. In the case of D1 bone density, use the cortical drill (TFRKC48) up to the black laser marking (recommended n. revs = 200 rpm).
8. Insert the implant using the drivers (TSKDR/TSKINS). Recommended n. of revs 15-25 rpm.
9. Close with the screw cap included in the package.